Print Report | Back to Test Summary

Testing Report for 2016-11-10-2-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081F1104
EFIS: 0814000160
Project ID: 211393
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-38-38.6-L5759
Work Description: CONSTRUCT A SAND HOUSE AND CHAIN LINK FENCE AT ONYX SUMMIT
Location Description: SAN BERNARDINO COUNTY AT ONYX SUMMIT 0.7 MILES SOUTH OF PIPES ROAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Al-Hakem Alina
Structure Rep.: Al-Hakem Alina

Sample Information

DIME Sample ID: 2016-11-10-2
TL Number from the TL Form: 02
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 11/10/2016
Date that the sample was received by the laboratory/organization performing the testing: 11/14/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 949-02
Structure unique identifier: ONYX SUMMIT SAND HOUSE
Structure name: SLAB
The fabricator/manufacturer/facility name: ROBERTSONS MIX

Material Information

The concrete mix design number: RRM09013
The truck number from where the sample was collected: 1169
The batch plant ticket number from where the sample was collected: 2319290
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TAIL GATE
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Information

DIME Test ID: 2016-11-10-2-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 12/8/2016
Verified Date: 1/3/2017
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength (to nearest 10 psi): 6130 psi
Maximum load on cylinder 1: 172370 lb
Maximum load on cylinder 2: 172260 lb
Compressive strength of cylinder 1: 6136.3 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 6132.4 psi
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data