Print Report | Back to Sample Detail

Sample Record for 2016-12-08-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210794 DEA: 062HT104 EFIS: 0612000287 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-99-23.5/26.7
Work Description: (Alternative Delivery) Realign Freeway CONTACT SMR PRIOR TO PERFORMING ANY TESTING OR INSPECTION. CMGC PROJECT. Realign Route 99 between Ashlan Avenue and Olive Avenue to accommodate the High Speed Train (HST).
Location Description: State Highway 99 in Fresno (Fresno County) from 0.2 miles North of Olive Ave over-crossing to 0.2 miles North of Ashlan Ave over-crossing.
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 2718 Granite Ct , Fresno, CA 93706
Resident Engineer: Justin Kimura Structure Rep.: Daniel Chapa

Sample Information

DIME Sample ID: 2016-12-08-2
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 12/08/2016
Date that the sample was received by the laboratory/organization performing the testing: 12/12/2016
The quantity of what the sample constitutes: 9
A brief description of the sample: Bearing Pad
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 15315-1, 2, 3, 4, 5, 6, 7, 8, 9
Material/Compound/Elastomer ID: NA
Samples Representing: 200
Description (size): 4.6" x 15" x 20" Various sizes
Comments: Unknown
Description (Number of Shims): 8
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2016-12-08-2-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 12/19/2016
Date Tested: 12/13/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 51
Reading #2 51
Reading #3 52
Reading #4 51
Reading #5 52
Mean 51.4

Test 2 of 4

DIME Test ID: 2016-12-08-2-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 12/19/2016
Date Tested: 12/13/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2KIP
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.073 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2950.8 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.068 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2764.7 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.077 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2746.1 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2764.7 lbf/in^2

Test 3 of 4

DIME Test ID: 2016-12-08-2-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 12/19/2016
Date Tested: 12/13/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM no data
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.073 in
Sample 1 Tear Strength 260.3 lbf / in
Sample 2 Median Thickness 0.07 in
Sample 2 Tear Strength 214.3 lbf / in
Sample 3 Median Thickness 0.075 in
Sample 3 Tear Strength 253.3 lbf / in
Median of the Tear Strength Values 253.3 lb/in

Test 4 of 4

DIME Test ID: 2016-12-08-2-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 12/19/2016
Date Tested: 12/15/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass