Print Report | Back to Test Summary

Testing Report for 2016-12-07-6-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 05330784
EFIS: 0512000076
Project ID: 211004
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-46-46.0/50.2
Work Description: CONVERT 2-LANE TO 4 LANE EXPRESSWAY.
Location Description: NEAR SHANDON FROM 0.2 MILE EAST OF MCMILLIAN CANYON ROAD TO 0.4 MILE WEST OF LUCY BROWN ROAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Amy Norris
Structure Rep.: Nick Heisdorf

Sample Information

DIME Sample ID: 2016-12-07-6
TL Number from the TL Form: C749159
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 12/7/2016
Date that the sample was received by the laboratory/organization performing the testing: 12/9/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: Bar Lock Couplers
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Gerdau Dayton Superior

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Gerdau
Coupler Manufacturer: Dayton Superior
Intermediate Assembler or Fabricator: Unknown
Rebar Size: #5
Coupler Model: Bar Lock Stanard Coupler
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): A145073
Rebar Heat Number(s): 6502502202
Rebar Size 2 :

Test Information

DIME Test ID: 2016-12-07-6-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Date Tested: 12/12/2016
Verified Date: 12/12/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Slip (inch) Peak Load (lbf) Peak Stress (psi) Comments Tested By
1 1 #5/16mm 0.31 -0.0036 28174 90884 Service Splice Fred
Temperature: 72 F
UTM: 400KIP
Halo ID: Small