Print Report | Back to Sample Detail

Sample Record for 2016-12-02-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210696 DEA: 080M2804 EFIS: 0800000472 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-171.8/173.8
Work Description: BRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT.
Location Description: In SBD County
Contractor Name: M.C.M. CONSTRUCTION, INC. - Dan Shaw
Contractor Address: P.O. Box 620, North Highlands, CA 95660
Resident Engineer: John Santos Structure Rep.: Faisal Zahlout

Sample Information

DIME Sample ID: 2016-12-02-3
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 12/02/2016
Date that the sample was received by the laboratory/organization performing the testing: 12/07/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: A536 Ductile Iron
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSI Dotson Iron

Material Information

Heat Number (s): 3276
Part Number (s): 68 19 216 248
Material Specification: A536
Grades: 65-45-12
Metal Foundry Manufacturer (Mill): Dotson Iron Castings
Prestressing Manufacturer: DSI

Test Results

Test 1 of 1

DIME Test ID: 2016-12-02-3-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 12/09/2016
Date Tested: 12/08/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 2
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
32760.4950.1924472898129012.1Fred
32760.4940.1917503878979010.6Fred
UTM 67KIP
Temperature 72 F