Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 041K8004 Cty NAP Rte 121 PM 16.7/16.9, 16.7/20.35 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Danilo Patenia |
Date Reported: |
12/07/2016 |
|
Address: |
TL Number: |
210254 |
||
City: |
||||
Project Name: Install temporary one-way traffic control signals, construct soldier pile retaining wall, reconstruct roadway, place RSP & perform miscellaneous related work |
||||
Prime Contractor: GORDON N BALL INC |
||||
Sample Taken Date: |
11/30/2016 |
Mix Design: |
CT1 MOD |
|
Contractor: Unknown |
Location: |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 95412 | 3363.1 | 1 |
2 | 6.01 | 28.37 | 97773 | 3446.4 | 1 |
DIME Test ID: 2016-11-30-3-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3400
Age of specimen: 7 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing