Print Report | Back to Sample Detail

Sample Record for 2016-10-26-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210696 DEA: 080M2804 EFIS: 0800000472 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-171.8/173.8
Work Description: BRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT.
Location Description: In SBD County
Contractor Name: M.C.M. CONSTRUCTION, INC. - Dan Shaw
Contractor Address: P.O. Box 620, North Highlands, CA 95660
Resident Engineer: John Santos Structure Rep.: Faisal Zahlout

Sample Information

DIME Sample ID: 2016-10-26-5
TL Number from the TL Form: 942-08
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/26/2016
Date that the sample was received by the laboratory/organization performing the testing: 10/31/2016
The quantity of what the sample constitutes: 8
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 942-08
Structure unique identifier: Unknown
Structure name: Unknown
The fabricator/manufacturer/facility name: On site

Material Information

The concrete mix design number: P40AF023SP
The truck number from where the sample was collected: 8049
The batch plant ticket number from where the sample was collected: AtJobsite
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 3

DIME Test ID: 2016-10-26-5-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Verified Date: 11/03/2016
Date Tested: 11/02/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Cross sectional area of cylinder 1 27.99 in^2
Cross sectional area of cylinder 2 27.99 in^2
Capped in accordance with? ASTM C617/CTM521
Compressive strength (to nearest 10 psi) 4400 psi
Average diameter of cylinder 1 5.97 in
Average diameter of cylinder 2 5.97 in
Compressive strength of cylinder 1 4364.4 psi
Compressive strength of cylinder 2 4434.8 psi
Maximum load on cylinder 1 122160 lb
Maximum load on cylinder 2 124130 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 7 days

Test 2 of 3

DIME Test ID: 2016-10-26-5-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Verified Date: 11/18/2016
Date Tested: 11/16/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Cross sectional area of cylinder 1 27.99 in^2
Cross sectional area of cylinder 2 28.09 in^2
Capped in accordance with? ASTM C617/CTM521
Compressive strength (to nearest 10 psi) 6020 psi
Average diameter of cylinder 1 5.97 in
Average diameter of cylinder 2 5.98 in
Compressive strength of cylinder 1 6010.7 psi
Compressive strength of cylinder 2 6022.1 psi
Maximum load on cylinder 1 168240 lb
Maximum load on cylinder 2 169160 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 21 days

Test 3 of 3

DIME Test ID: 2016-10-26-5-3
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Verified Date: 11/23/2016
Date Tested: 11/23/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 27.99 in^2
Capped in accordance with? ASTM C617/CTM521
Compressive strength (to nearest 10 psi) 6780 psi
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.97 in
Compressive strength of cylinder 1 6773.2 psi
Compressive strength of cylinder 2 6793.9 psi
Maximum load on cylinder 1 190260 lb
Maximum load on cylinder 2 190160 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 28 days