Sample Record for 2016-10-24-2
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 208944 DEA: 07187224 EFIS: 0700000189
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-126-R6.8/R9.2
Work Description: SR 126/Commerce Center Drive Interchange Project
Location Description: Northwest of the City of Santa Clarita in unincorporated Los Angeles County
Contractor Name: C.A. Rasmussen, Inc.
Contractor Address: 28548 Livingston Avenue, Valencia, CA 91355-4171
Resident Engineer: Daniel Widjaja Structure Rep.: Sarah Hartz
Sample Information
DIME Sample ID: 2016-10-24-2
TL Number from the TL Form: C927503
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 10/24/2016
Date that the sample was received by the laboratory/organization performing the testing: 10/25/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: Epoxy Coated Dowel
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dayton
Material Information
Dowel Metal Heat Number: SE16103106
Dowel Epoxy Batch Number: Unknown
Dowel Coating Specification: ASTM A934
Dowel Size: 1.5 in
Dowel Coating Color: Purple
Dowel Manufacturer: Dayton Superior
Dowel Coater: Dayton Superior
Release Number: 1270712-2
Quality Assurance Code: Unknown
Rebar Size (#):
Test Results
Test 1 of 2
DIME Test ID: 2016-10-24-2-1
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 10/27/2016
Date Tested: 10/26/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
First Bar Mean
|
13.07 mils
|
Second Bar Mean
|
10.58 mils
|
Lower spec. limit LSL
|
7 mils
|
Upper spec. limit USL
|
40 mils
|
Total mean value
|
11.82 mils
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
Test 2 of 2
DIME Test ID: 2016-10-24-2-2
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 10/27/2016
Date Tested: 10/26/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
3 ft
|
Holidays Per Linear Foot of Bar
|
0 holiday per ft
|
Holiday Test Pass/Fail
|
Pass
|