Testing Report for 2016-09-28-18-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07274804
EFIS: 0700000516
Project ID: 209918
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-18-0.2
Work Description: REPLACE BRIDGE DECK AND RAILING, REPAIR BENT CAPS AND COLUMNS.
Location Description: LOS ANGELES COUNTY AT LLANO AT COUNTY LINE OVERHEAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mansukh Vazirani
Structure Rep.: Sarah Hartz

Sample Information

DIME Sample ID: 2016-09-28-18
TL Number from the TL Form: 786-A1
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 9/28/2016
Date that the sample was received by the laboratory/organization performing the testing: 9/30/2016
The quantity of what the sample constitutes: 10
A brief description of the sample: Concrete 6 x 12 Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 936-A1
Structure unique identifier: Unknown
Structure name: Unknown
The fabricator/manufacturer/facility name: HI GRADE MATERIALS

Material Information

The concrete mix design number: SITI72A2
The truck number from where the sample was collected: 185
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: BRIDGE DECK REPLACEMENT LIANO CALIFORNIA
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Information

DIME Test ID: 2016-09-28-18-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 10/10/2016
Verified Date: 10/13/2016
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength (to nearest 10 psi): 3910 psi
Maximum load on cylinder 1: 110050 lb
Maximum load on cylinder 2: 112630 lb
Compressive strength of cylinder 1: 3866.8 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 3957.5 psi
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 12 days
Age of specimen in hours: no data