Print Report | Back to Test Summary

Testing Report for 2016-09-07-6-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 043G4574
EFIS: 0412000057
Project ID: 210734
QA Service Level: 1
DIST-CO-RTE-PM: 04-CC,MRN,SF-580,580,80-580PM6.1/7.8,0.0/2.6,80PM5.7/7.7
Work Description: REPLACE JOINT SEALS, CONSTRUCT APPROACH SLAB, REPAIR DECK DRAINS
Location Description: IN CONTRA COSTA, MARIN, AND SAN FRANCISCO COUNTIES ON THE SANFRANCISCO-OAKLAND BAY BRIDGE ANDRICHMOND -SAN RAFAEL BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Ranjeet singh
Structure Rep.: Pervez Randhawa

Sample Information

DIME Sample ID: 2016-09-07-6
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 9/7/2016
Date that the sample was received by the laboratory/organization performing the testing: 9/22/2016
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: D S Brown

Material Information

Mfg. Lot Number(s): C1609-6071-24
Material/Compound/Elastomer ID: NA
Samples Representing: 83
Description (size): .5in x 6in x 6in
Comments: Unknown
Description (Number of Shims): 0
Type of Bearing Pad: Plain
Description (Thickness of Shims): NA
Manufacturer(s): D S Brown
Batch Number: NA

Test Information

DIME Test ID: 2016-09-07-6-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Date Tested: 9/22/2016
Verified Date: 9/29/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of specimens tested: 3
UTM: no data
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.078 in
Sample 1 Tear Strength: 269.2 lbf / in
Sample 2 Median Thickness: 0.077 in
Sample 2 Tear Strength: 259.7 lbf / in
Sample 3 Median Thickness: 0.07 in
Sample 3 Tear Strength: 257.1 lbf / in
Median of the Tear Strength Values: 259.7 lb/in