Print Report | Back to Sample Detail

Sample Record for 2016-09-13-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209217 DEA: 080F5404 EFIS: 0800000136 COOP: 081468 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-91,15-0.0/13.04, 35.64/45.14
Work Description: SR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description: 08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
Contractor Name: Atkinson Walsh, Joint Venture
Contractor Address: 1785 Sampson Ave, Corona, CA 92879
Resident Engineer: Richard Hebert Structure Rep.: Cyrus Shahinpar

Sample Information

DIME Sample ID: 2016-09-13-4
TL Number from the TL Form: C939801
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 09/13/2016
Date that the sample was received by the laboratory/organization performing the testing: 09/16/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: Threaded Bar
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Gerdau

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type: Deformed
Rebar Size: 1-1/4"
Nut Specification for Threaded Bar: NA
System Manufacturer: DSI
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s):
Nut Heat Number(s):
Bar Lot Number:
Nut Lot Number:
Coupler Heat Number(s):
Coupler Grade:

Test Results

Test 1 of 2

DIME Test ID: 2016-09-13-4-1
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 09/19/2016
Date Tested: 09/19/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A722 Bar
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
1A722 DSI 1.250\" Threaded Bar Bar Heat #62138789051.071646771498783.533A722 BarFred
Temperature 72 F
UTM 400KIP

Test 2 of 2

DIME Test ID: 2016-09-13-4-2
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 09/19/2016
Date Tested: 09/19/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A722 Bar & Coupler
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
2A722 DSI 1.250\" Threaded Bar, Coupler Bar Heat #6213878905, Coupler #1.25162232146507720A722 Bar & CouplerFred
Temperature 72 F
UTM 400KIP