Print Report | Back to Test Summary

Testing Report for 2016-07-16-1-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07121844
EFIS: 0700000117
Project ID: 3807
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-42.8/47.3
Work Description: CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: James Shih
Structure Rep.: Matthew Remo

Sample Information

DIME Sample ID: 2016-07-16-1
TL Number from the TL Form: C952637 thru C952648
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Steel Check Sample Plate
Sample Taken Date: 7/16/2016
Date that the sample was received by the laboratory/organization performing the testing: 7/26/2016
The quantity of what the sample constitutes: 12
A brief description of the sample: Check Sample Plates
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Stinger Bridge Iron

Material Information

Heat Number(s): 2U133-403, 2U025-902, 2U036-503, 2U229-203, 2
Material Specification: A709
Grade: 50
Thickness: .5in .625in 1in 1.25in
Shape: Square
Metal Foundry Manufacturer (Mill): EVRAZ
Plate Dimension: 12in x 12in

Test Information

DIME Test ID: 2016-07-16-1-3
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Date Tested: 8/4/2016
Verified Date: 8/9/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Heat 2U133
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Temperature Required: 40 oF
Minimum Energy Required: 25 ftlb
Test Temperature 1: 39.8 oF
Impact Energy 1: 129 ftlb
Impact Energy 2: 109 ftlb
Impact Energy 3: 271 ftlb
Average Impact Energy: 170 ftlb
Striker Radius: 8 mm
Value Exceeds The Machine Capacity?: No