Print Report | Back to Sample Detail

Sample Record for 2016-07-20-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210808 DEA: 020E0904 EFIS: 0200000016 QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-5-R29.3/R31.1,R45.0/R45.8
Work Description: REPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT
Location Description: IN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE.
Contractor Name: GOLDEN STATE BRIDGE, INC.
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Nathan Alexander Structure Rep.: Christopher S 'Chris' Brace

Sample Information

DIME Sample ID: 2016-07-20-4
TL Number from the TL Form: C741251
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 07/20/2016
Date that the sample was received by the laboratory/organization performing the testing: 07/22/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: End Anchors
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dextra America Nucor

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): SE15104965
Head Manufacturer Lot Number(s): 3580
Rebar Size: #11
Headed Bar Model Name: Bartec
Size of Head: Full Size - 9x
Head Connection Type: Threaded
Head Shape: Circular
Rebar Manufacturer: Nucor
Head Manufacturer: Dextra America
Head Fabricator: Dextra
Material Standard Code: ASTM A706
Headed Bar Unique ID:

Test Results

Test 1 of 3

DIME Test ID: 2016-07-20-4-1
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/26/2016
Date Tested: 07/25/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
T091.5615547099660Bar BrokeFred
Temperature 72 F
UTM 400KIP

Test 2 of 3

DIME Test ID: 2016-07-20-4-2
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/26/2016
Date Tested: 07/25/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
T091.5615447099020Bar BrokeFred
Temperature 72 F
UTM 400KIP

Test 3 of 3

DIME Test ID: 2016-07-20-4-3
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/26/2016
Date Tested: 07/25/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
T091.5615229097620Bar BrokeFred
Temperature 72 F
UTM 400KIP