Project Information

Project ID: 210862 DEA: 031F4004 EFIS: 0300020420 QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA-80-35.1/38.3
Work Description: WIDEN EASTBOUND ROADWAY
Location Description: WIDEN EASTBOUND ROADWAY
Contractor Name: A. TEICHERT & SON, INC. DBA TEICHERT CONSTRUCTION
Contractor Address: 400 Sunrise Ave. Ste. 300, Roseville, CA 95661
Resident Engineer: Phil Zink Structure Rep.: Carl Anderson

Sample Information

DIME Sample ID: 2016-07-08-14
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 07/08/2016
Date that the sample was received by the laboratory/organization performing the testing: 07/11/2016
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 14926-1
Material/Compound/Elastomer ID: NA
Samples Representing: 1
Description (size): 1in x 12in x 12in
Comments: Unknown
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2016-07-08-14-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 07/22/2016
Date Tested: 07/20/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 51
Reading #2 50
Reading #3 52
Reading #4 52
Reading #5 50
Mean 51

Test 2 of 4

DIME Test ID: 2016-07-08-14-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 07/22/2016
Date Tested: 07/20/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2KIP
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.067 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 3035.7 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.067 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 3392.9 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.066 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 3272.7 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 3272.7 lbf/in^2

Test 3 of 4

DIME Test ID: 2016-07-08-14-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 07/22/2016
Date Tested: 07/20/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM no data
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.061 in
Sample 1 Tear Strength 229.5 lbf / in
Sample 2 Median Thickness 0.063 in
Sample 2 Tear Strength 222.2 lbf / in
Sample 3 Median Thickness 0.072 in
Sample 3 Tear Strength 236.1 lbf / in
Median of the Tear Strength Values 229.5 lb/in

Test 4 of 4

DIME Test ID: 2016-07-08-14-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 07/22/2016
Date Tested: 07/21/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass