Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042G5214 Cty ALA Rte 580 PM I-580(PM19.4/46.0)&I-680(PM3.3/21.7) Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Wondwosen Alemayehu |
Date Reported: |
07/08/2016 |
|
Address: |
TL Number: |
044659 |
||
City: |
||||
Project Name: UPGRADE TRANSITION RAILING AT VARIOUS LOCATIONS |
||||
Prime Contractor: DIRT AND AGGREGATE INTERCHANGE, INC. |
||||
Sample Taken Date: |
06/10/2016 |
Mix Design: |
1412879 |
|
Contractor: Unknown |
Location: ALAMEDA COUNTY AT VARIOUS LOCATIONS |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.99 | 28.18 | 146173 | 5187.1 | 1 |
2 | 6.00 | 28.27 | 153907 | 5444.2 | 1 |
DIME Test ID: 2016-06-10-15-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5320
Age of specimen: 28 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing