Print Report | Back to Test Summary

Testing Report for 2016-06-10-14-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 11263304
EFIS: 1100000743
Project ID: 209576
QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-8-R38.8/R39.1
Work Description: BRIDGE REPLACEMENT AND MODIFY INTERCHANGE.
Location Description: IMPERIAL COUNTY IN EL CENTRO FROM 0.2 MILE WEST TO 0.1 MILE EAST OF DOGWOOD ROAD OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Daniel Hernandez Duarte
Structure Rep.: Alex Balce

Sample Information

DIME Sample ID: 2016-06-10-14
TL Number from the TL Form: C384238
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 6/10/2016
Date that the sample was received by the laboratory/organization performing the testing: 6/22/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: Lenton Couplers
From where was the sample collected: Job Site
Laboratory sample identification: 1
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC Rbar

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: CMC Rebar
Coupler Manufacturer: Erico
Intermediate Assembler or Fabricator: CMC Rebar
Rebar Size: #11
Coupler Model: Lenton
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): L8755
Rebar Heat Number(s): 4055184
Rebar Size 2 : NA

Test Information

DIME Test ID: 2016-06-10-14-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Date Tested: 6/23/2016
Verified Date: 6/23/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Slip (inch) Peak Load (lbf) Peak Stress (psi) Comments Tested By
2 1 #11/36mm 1.56 0 139112 89174 Service Splice Brian
Temperature: 72 F
UTM: 2000KIP
Halo ID: Big