Print Report | Back to Test Summary

Testing Report for 2016-06-13-7-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 11413604
EFIS: 1113000036
Project ID: 210771
QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-8,154-R45.5/R55.0
Work Description: CONSTRUCT CRCP, HMA-A, GUARDRAIL, RUMBLE STRIPS AND APPROACH SLABS
Location Description: IN IMPERIAL COUNTY NEAR EL CENTRO FROM 0.6 MILE WEST OF ANDERHOLT ROAD OVERCROSSING TO 0.5 MILE EAST OF EAST HIGHLINE CANAL BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Dan Juarez
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2016-06-13-7
TL Number from the TL Form: C953729
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 6/13/2016
Date that the sample was received by the laboratory/organization performing the testing: 6/20/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: Flash Welded Rebar Hoops
From where was the sample collected: Source
Laboratory sample identification: 1 2
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 043916
Hoop Manufacturer Lot Number(s): 1 2
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: 4
Diameter of Hoop: 2'-2"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Cascade
Welding Company: TNT Rebar
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Information

DIME Test ID: 2016-06-13-7-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Date Tested: 6/22/2016
Verified Date: 6/22/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: necking okay
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
3 1 #4/13mm 0.2 18280 91400 necking okay Fred
UTM: 75KIP
Temperature: 72 F