Print Report | Back to Test Summary

Testing Report for 2016-06-15-6-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 040120T4
EFIS: 0400000027
Project ID: 7285
QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-12.6/13.9
Work Description: CONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location Description: THE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Tom Larwin
Structure Rep.: Mehran Ardakanian

Sample Information

DIME Sample ID: 2016-06-15-6
TL Number from the TL Form: C939570
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 6/15/2016
Date that the sample was received by the laboratory/organization performing the testing: 6/17/2016
The quantity of what the sample constitutes: 32
A brief description of the sample: Headed Bars
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: HRC

Material Information

Production or Authorization Testing: Authorization Testing
Rebar Heat Number(s): 4049732
Head Manufacturer Lot Number(s): 1
Rebar Size: #10
Headed Bar Model Name: HRC 120
Size of Head: Reduced Size - 4x
Head Connection Type: Friction Weld
Head Shape: Square
Rebar Manufacturer: CMC
Head Manufacturer: HRC
Head Fabricator: HRC
Material Standard Code: ASTM A706

Test Information

DIME Test ID: 2016-06-15-6-2
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 6/22/2016
Verified Date: 6/22/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Number of Headed Bar Samples: 1
Lot # Area (sqin) Peak Load (lbf) Tensile Strength (psi) Comments Tested By
1.27 115570 91000 Bar Broke Brian
Temperature: 72 F
UTM: 2000KIP