Project Information

Project ID: 210678 DEA: 030G0504 EFIS: 0314000029 QA Service Level: 1
DIST-CO-RTE-PM: 03-YOL-5,113-Var
Work Description: OVERLAY 15 BRIDGE DECKS WITH POLYESTER AND METHACRYLATE
Location Description: YOLO COUNTY IN AND NEAR WOODLAND AT VARIOUS LOCATIONS
Contractor Name: AMERICAN CIVIL CONSTRUCTORS WEST COAST LLC
Contractor Address: 2990 Bay Vista Ct. Ste. D., Benicia, CA 94510-1195
Resident Engineer: Mohssen Ghassemi Structure Rep.: Thu Pham

Sample Information

DIME Sample ID: 2016-05-06-5
TL Number from the TL Form: C240493
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 594-1991
Type of Sample: Quality Assurance
Type of Material: Polyester
Sample Taken Date: 05/06/2016
Date that the sample was received by the laboratory/organization performing the testing: 05/10/2016
The quantity of what the sample constitutes: 1gallon
A brief description of the sample: polyester resin
From where was the sample collected: Distributor
Laboratory sample identification: 16-057
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: reichhold

Material Information

Mfg. Lot Number(s): 0000000
Batch number: 0000974651
Mix number:

Test Results

Test 1 of 6

DIME Test ID: 2016-05-06-5-1
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 06/17/2016
Date Tested: 06/08/2016
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Density Units grams/milliliters
Liquid Density (grams per milliliter) 1.09

Test 2 of 6

DIME Test ID: 2016-05-06-5-3
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 06/17/2016
Date Tested: 06/17/2016
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 45

Test 3 of 6

DIME Test ID: 2016-05-06-5-4
Test Method: ASTM D618-Jun13: Standard Practice for Conditioning Plastics for Testing
Verified Date: 06/17/2016
Date Tested: 06/17/2016
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Conditioning procedure 1825502570
Conditioning time used 1825502570
Conditioning temperature 70
Conditioning relative humidity 30

Test 4 of 6

DIME Test ID: 2016-05-06-5-5
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 06/17/2016
Date Tested: 06/17/2016
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 6
Conditioning procedure 25570
Speed of testing 0.45 in per min
Sample 1 Width 0.501 in
Sample 1 Ultimate strength 3097 psi
Sample 1 Thickness 0.251 in
Sample 1 Area 0.1258 in^2
Sample 1 Ultimate Strength Actual 389.6 psi
Sample 1 percent elongation 57 %
Sample 1 Time 4.21 minute
Sample 2 Width 0.494 in
Sample 2 Thickness 0.249 in
Sample 2 Area 0.123 in^2
Sample 2 Ultimate strength 3089 psi
Sample 2 Ultimate Strength Actual 379.9 psi
Sample 2 percent elongation 60.9 %
Sample 2 Time 4.24 minute
Sample 3 Width 0.493 in
Sample 3 Thickness 0.254 in
Sample 3 Area 0.1252 in^2
Sample 3 Ultimate strength 2736 psi
Sample 3 Ultimate Strength Actual 242.6 psi
Sample 3 percent elongation 42.9 %
Sample 3 Time 2.49 minute
Sample 4 Width 0.493 in
Sample 4 Thickness 0.251 in
Sample 4 Area 0.1237 in^2
Sample 4 Ultimate strength 2746 psi
Sample 4 Ultimate Strength Actual 339.7 psi
Sample 4 percent elongation 46.5 %
Sample 4 Time 3.13 minute
Sample 5 Width 0.494 in
Sample 5 Thickness 0.255 in
Sample 5 Area 0.126 in^2
Sample 5 Ultimate strength 3138 psi
Sample 5 Ultimate Strength Actual 395.4 psi
Sample 5 percent elongation 60.4 %
Sample 5 Time 4.41 minute
Sample 6 Width 0.494 in
Sample 6 Thickness 0.258 in
Sample 6 Area 0.1275 in^2
Sample 6 Ultimate strength 2699 psi
Sample 6 Ultimate Strength Actual 344.1 psi
Sample 6 percent elongation 51.6 %
Sample 6 Time 3.26 minute
Ultimate Strength Average 2917 psi
Percent Elongation Average 53.2 %

Test 5 of 6

DIME Test ID: 2016-05-06-5-6
Test Method: CONCLP 1-16: Polyester Resin Patching Materials
Verified Date: 06/17/2016
Date Tested: 06/17/2016
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Type b-11
Sand Percent 67 %
Sand Weight 3632 g
Aggregate Type s-39
Aggregate Percent 33 %
Aggregate Weight 1816 g
Resin Percent 12 %
Resin Weight 654 g
MEKP Percent 2 %
MEKP Weight 13.1 g
Time Started 0930
Test 1 psi 482
Test 2 psi 536
Test 3 psi 518
Average psi 512

Test 6 of 6

DIME Test ID: 2016-05-06-5-7
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 06/17/2016
Date Tested: 06/17/2016
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 154 mm
Room Temperature 76 f
Tare weight no data
Initial weight 100.3 grams
Weight at 5 minutes 100.2 grams
Weight at 10 minutes 100.1 grams
Weight at 15 minutes 100 grams
Weight at 20 minutes 99.8 grams
Weight at 25 minutes 99.7 grams
Weight at 30 minutes 99.6 grams
Final weight 99.6 grams
Total weight loss 0.7 grams
Calculated radius of gallon can lid in cm 7.7 cm
Lid Factor 53.687 m^2
Volatile emission 37.581 grams/m^2

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2016-05-06-5-2ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer06/09/2016Not scheduledMike MullinsCT HQ - Sacramento Concrete Testing Laboratory