Print Report | Back to Test Summary

Testing Report for 2016-05-27-5-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080F5404
EFIS: 0800000136
Project ID: 209217
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-91,15-0.0/13.04, 35.64/45.14
Work Description: SR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description: 08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Salim Khalil
Structure Rep.: Alex Angha

Sample Information

DIME Sample ID: 2016-05-27-5
TL Number from the TL Form: SRL205
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 5/27/2016
Date that the sample was received by the laboratory/organization performing the testing: 5/31/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: Concrete Cylinder 6 x 12
From where was the sample collected: Job Site
Laboratory sample identification: 888-SRL205
Structure unique identifier: Unknown
Structure name: Unknown
The fabricator/manufacturer/facility name: HOLLIDAY ROCK

Material Information

The concrete mix design number: CM5640
The truck number from where the sample was collected: RT 43
The batch plant ticket number from where the sample was collected: 118047749
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: LOAD 4
Where the material sample would have been placed if not sampled: BR 32 ABUT 2 FTG
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Information

DIME Test ID: 2016-05-27-5-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 6/10/2016
Verified Date: 6/13/2016
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 5.99 in
Cross sectional area of cylinder 1: 28.18 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength (to nearest 10 psi): 4240 psi
Maximum load on cylinder 1: 117330 lb
Maximum load on cylinder 2: 121480 lb
Compressive strength of cylinder 1: 4163.6 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 4310.9 psi
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 14 days
Age of specimen in hours: no data