Print Report | Back to Sample Detail

Sample Record for 2016-06-06-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210698 DEA: 11299204 EFIS: 1100000422 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-94,805-Var
Work Description: SEISMIC RETROFIT 4 BRIDGES ON ROUTES 94 AND 805.
Location Description: IN SAN DIEGO COUNTY AT VARIOUS LOCATIONS
Contractor Name: FUTURE DB INTERNATIONAL INC
Contractor Address: 8707 RESEARCH DR, IRVINE CA 92618
Resident Engineer: Brian Martin Structure Rep.: Hamid Akbarzadegan

Sample Information

DIME Sample ID: 2016-06-06-4
TL Number from the TL Form: C958028
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 06/06/2016
Date that the sample was received by the laboratory/organization performing the testing: 06/08/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: Couplers
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific Steel

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Nucor
Coupler Manufacturer: HRC
Intermediate Assembler or Fabricator: Unknown
Rebar Size: #9
Coupler Model: 500-510
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Nucor
Coupler Component Heat/Lot Number(s): 0K1753, 75061855
Rebar Heat Number(s): PL16201548, PL16101523
Rebar Size 2 : NA
Coupler Unique ID:

Test Results

Test 1 of 3

DIME Test ID: 2016-06-06-4-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 06/09/2016
Date Tested: 06/09/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke,Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1NA#9/29mm1-0.00299614896148Bar Broke,Ok Necking
Temperature 72 F
UTM 400KIP
Halo ID Small

Test 2 of 3

DIME Test ID: 2016-06-06-4-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 06/09/2016
Date Tested: 06/09/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke,Ok necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
2NA#9/29mm109841198411Bar Broke,Ok necking
Temperature 72 F
UTM 400KIP
Halo ID Small

Test 3 of 3

DIME Test ID: 2016-06-06-4-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 06/09/2016
Date Tested: 06/09/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke,Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
3NA#9/29mm109865298652Bar Broke,Ok Necking
Temperature 72 F
UTM 400KIP
Halo ID Small