Print Report | Back to Test Summary

Testing Report for 2016-05-10-6-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 083401U4
EFIS: 0800000609
Project ID: 208682
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-138,138-6.2/6.4,2.3/R15.2
Work Description: WIDEN TO 4 LNS FR BEEKLEY RD TO JCT 15, ADD 1 LN EB FR PHELAN RD TO
Location Description: SAN BERNARDINO COUNTY ON ROUTE 138 NEAR PHELAN FROM 0.6 MILE WEST OF PHELAN ROAD TO THE JUNCTION OF ROUTE 15 AND ON ROUTE 2 FROM 0.1 MILE NORTH OF WILD HORSE CANYON ROAD TO ROUTE 138
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Elvira Lenart
Structure Rep.: Osama Abdalla

Sample Information

DIME Sample ID: 2016-05-10-6
TL Number from the TL Form: 1
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 5/10/2016
Date that the sample was received by the laboratory/organization performing the testing: 5/13/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 908-01
Structure unique identifier: RW FOOTING AT ABUT 1AND2
Structure name: WILD LIFE UC 2
The fabricator/manufacturer/facility name: np

Material Information

The concrete mix design number: siti72a
The truck number from where the sample was collected: 0
The batch plant ticket number from where the sample was collected: 726889
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: LOAD 4
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Information

DIME Test ID: 2016-05-10-6-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 6/7/2016
Verified Date: 6/7/2016
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength (to nearest 10 psi): 5130 psi
Maximum load on cylinder 1: 150030 lb
Maximum load on cylinder 2: 138260 lb
Compressive strength of cylinder 1: 5341.0 psi
Type of fracture pattern of cylinder 1: 3
Compressive strength of cylinder 2: 4922.0 psi
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data