Print Report | Back to Sample Detail

Sample Record for 2016-05-13-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210682 DEA: 041SS414 EFIS: 0413000228 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-13-4.9
Work Description: CONSTRUCT SOLDIER PILE RETAINING WALL AND RECONSTRUCT SHOULDER..
Location Description: CONSTRUCT SOLDIER PILE RETAINING WALL AND RECONSTRUCT SHOULDER.
Contractor Name: GORDON N. BALL, INC.
Contractor Address: 333 CAMILLE AVENUE, ALAMO, CA 94507
Resident Engineer: Jason Trinh Structure Rep.: Saman Soheilifard

Sample Information

DIME Sample ID: 2016-05-13-7
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 05/13/2016
Date that the sample was received by the laboratory/organization performing the testing: 05/17/2016
The quantity of what the sample constitutes: 31
A brief description of the sample: Bearing Pad
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 132517
Material/Compound/Elastomer ID: NA
Samples Representing: 31
Description (size): 1.15in x 8in x 12in
Comments: Unknown
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2016-05-13-7-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 05/24/2016
Date Tested: 05/18/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 54
Reading #2 55
Reading #3 55
Reading #4 54
Reading #5 55
Mean 54.6

Test 2 of 4

DIME Test ID: 2016-05-13-7-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 05/24/2016
Date Tested: 05/18/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2KIP
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.068 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2882.4 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.065 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 3435.6 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.07 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 3200 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 3200 lbf/in^2

Test 3 of 4

DIME Test ID: 2016-05-13-7-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 05/24/2016
Date Tested: 05/18/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 3
UTM 2KIP
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.07 in
Sample 1 Tear Strength 257.1 lbf / in
Sample 2 Median Thickness 0.068 in
Sample 2 Tear Strength 264.7 lbf / in
Sample 3 Median Thickness 0.066 in
Sample 3 Tear Strength 272.7 lbf / in
Median of the Tear Strength Values 264.7 lb/in

Test 4 of 4

DIME Test ID: 2016-05-13-7-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 05/24/2016
Date Tested: 05/23/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass