Print Report | Back to Test Summary

Testing Report for 2016-03-21-2-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080F5404
EFIS: 0800000136
Project ID: 209217
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-91,15-0.0/13.04, 35.64/45.14
Work Description: SR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description: 08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Salim Khalil
Structure Rep.: Alex Angha

Sample Information

DIME Sample ID: 2016-03-21-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 3/21/2016
Date that the sample was received by the laboratory/organization performing the testing: 3/22/2016
The quantity of what the sample constitutes: 7
A brief description of the sample: Bearing Pad
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 14646-1
Material/Compound/Elastomer ID: NA
Samples Representing: 7
Description (size): 4in x 16in x 22in
Comments: Unknown
Description (Number of Shims): 8
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): scougal Rubber
Batch Number: NA

Test Information

DIME Test ID: 2016-03-21-2-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Date Tested: 3/28/2016
Verified Date: 4/5/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Number of specimens tested: 3
UTM: 2KIP
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.068 in
Sample 1 Tear Strength: 235.3 lbf / in
Sample 2 Median Thickness: 0.064 in
Sample 2 Tear Strength: 250 lbf / in
Sample 3 Median Thickness: 0.064 in
Sample 3 Tear Strength: 250 lbf / in
Median of the Tear Strength Values: 250 lb/in