Print Report | Back to Test Summary

Testing Report for 2016-01-13-1-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07288604
EFIS: 0700021080
Project ID: 208945
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer:
Structure Rep.:

Sample Information

DIME Sample ID: 2016-01-13-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 1/13/2016
Date that the sample was received by the laboratory/organization performing the testing: 1/15/2016
The quantity of what the sample constitutes: 7
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments: Unknown
Reel/Coil/Pack Number(s): S333569-2 S377355-5
Number of Coils: 2
Group Number: NA
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0536215-2 S0591115
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden

Test Information

DIME Test ID: 2016-01-13-1-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Date Tested: 1/18/2016
Verified Date: 1/19/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 4
Dia of the Center Wire (in) Dia of the Outer Wire 1 (in) Dia of the Outer Wire 2 (in) Dia of the Outer Wire 3 (in) Dia of the Outer Wire 4 (in) Dia of the Outer Wire 5 (in) Dia of the Outer Wire 6 (in) Area (sqin)
.207 .197 .197 .197 .197 .197 .197 0.217
.207 .197 .197 .197 .197 .197 .197 0.217
.208 .198 .197 .197 .197 .197 .197 0.217
.208 .197 .197 .198 .197 .197 .197 0.217