Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215621 DEA: 010J8704 EFIS: 0119000117
QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-101,271-VAR
Work Description: PLACE HMA, POLYESTER CONCRETE OVERLAY AND COLD PLANE.
Location Description: MENDOCINO COUNTY AT VARIOUS LOCATIONS
Contractor Name: TRUESDELL CORP OF CALIFORNIA INC
Contractor Address: 1310 W 23RD STREET, TEMPE AZ 85282
Resident Engineer: Mike Anderson Structure Rep.: Kari Forbes
DIME Sample ID: 2021-10-19-4
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 10/19/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/19/2021
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers and Polynt
DIME Test ID: 2021-10-19-4-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2021-10-19-4-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Density Units
|
pounds/gallons
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2021-10-19-4-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
5
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.486 in
|
Sample 1 Ultimate strength
|
3319.6 psi
|
Sample 1 Thickness
|
0.256 in
|
Sample 1 Area
|
0.1244 in^2
|
Sample 1 Ultimate Strength Actual
|
412.96 lbs
|
Sample 1 percent elongation
|
66.11 %
|
Sample 1 Time
|
0 MM:SS
|
Sample 2 Width
|
0.488 in
|
Sample 2 Thickness
|
0.258 in
|
Sample 2 Area
|
0.1259 in^2
|
Sample 2 Ultimate strength
|
3242.7 psi
|
Sample 2 Ultimate Strength Actual
|
408.26 lbs
|
Sample 2 percent elongation
|
64.29 %
|
Sample 2 Time
|
0 MM:SS
|
Sample 3 Width
|
0.486 in
|
Sample 3 Thickness
|
0.247 in
|
Sample 3 Area
|
0.12 in^2
|
Sample 3 Ultimate strength
|
3395 psi
|
Sample 3 Ultimate Strength Actual
|
407.4 lbs
|
Sample 3 percent elongation
|
66.24 %
|
Sample 3 Time
|
0 MM:SS
|
Sample 4 Width
|
0.487 in
|
Sample 4 Thickness
|
0.25 in
|
Sample 4 Area
|
0.1218 in^2
|
Sample 4 Ultimate strength
|
3172.9 psi
|
Sample 4 Ultimate Strength Actual
|
386.46 lbs
|
Sample 4 percent elongation
|
60.13 %
|
Sample 4 Time
|
0 MM:SS
|
Sample 5 Width
|
0.487 in
|
Sample 5 Thickness
|
0.253 in
|
Sample 5 Area
|
0.1232 in^2
|
Sample 5 Ultimate strength
|
3521.1 psi
|
Sample 5 Ultimate Strength Actual
|
433.8 lbs
|
Sample 5 percent elongation
|
69.45 %
|
Sample 5 Time
|
0 MM:SS
|
Ultimate Strength Average
|
3330 psi
|
Percent Elongation Average
|
65 %
|
DIME Test ID: 2021-10-19-4-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination
|
46
|
DIME Test ID: 2021-10-19-4-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1
|
24hr
|
Maximum applied load (P) for Sample 1
|
1643.74 lb
|
Span length for Sample 1
|
9 in
|
Break location for Sample 1
|
PCC
|
Specimen defects/notes for Sample 1
|
no data
|
Surface type for Sample 1
|
SSD
|
Modulus of rupture (R) for Sample 1
|
821.87 psi
|
Curing history for Sample 2
|
24hr
|
Maximum applied load (P) for Sample 2
|
1469.41 lb
|
Span length for Sample 2
|
9 in
|
Break location for Sample 2
|
PCC
|
Specimen defects/notes for Sample 2
|
no data
|
Surface type for Sample 2
|
SSD
|
Modulus of rupture (R) for Sample 2
|
734.705 psi
|
Curing history for Sample 3
|
24hr
|
Maximum applied load (P) for Sample 3
|
1334.03 lb
|
Span length for Sample 3
|
9 in
|
Break location for Sample 3
|
PCC
|
Specimen defects/notes for Sample 3
|
no data
|
Surface type for Sample 3
|
SSD
|
Modulus of rupture (R) for Sample 3
|
667.015 psi
|
DIME Test ID: 2021-10-19-4-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid
|
153.9 mm
|
Room Temperature
|
75 f
|
Tare weight
|
0 grams
|
Initial weight
|
100 grams
|
Weight at 5 minutes
|
99.948 grams
|
Weight at 10 minutes
|
99.883 grams
|
Weight at 15 minutes
|
99.826 grams
|
Weight at 20 minutes
|
99.773 grams
|
Weight at 25 minutes
|
99.719 grams
|
Weight at 30 minutes
|
99.665 grams
|
Final weight
|
99.67 grams
|
Total weight loss
|
0.33 grams
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
Lid Factor
|
53.757 m^2
|
Volatile emission
|
17.74 grams/m^2
|