Testing Report for 2015-12-07-1-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 083401U4
EFIS: 0800000609
Project ID: 208682
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-138,138-6.2/6.4,2.3/R15.2
Work Description: WIDEN TO 4 LNS FR BEEKLEY RD TO JCT 15, ADD 1 LN EB FR PHELAN RD TO
Location Description: SAN BERNARDINO COUNTY ON ROUTE 138 NEAR PHELAN FROM 0.6 MILE WEST OF PHELAN ROAD TO THE JUNCTION OF ROUTE 15 AND ON ROUTE 2 FROM 0.1 MILE NORTH OF WILD HORSE CANYON ROAD TO ROUTE 138
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Elvira Lenart
Structure Rep.: Osama Abdalla

Sample Information

DIME Sample ID: 2015-12-07-1
TL Number from the TL Form: 03
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 12/7/2015
Date that the sample was received by the laboratory/organization performing the testing: 12/9/2015
The quantity of what the sample constitutes: 6
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 908-3
Structure unique identifier: DS 29 WEST OF BECKEY
Structure name: Unknown
The fabricator/manufacturer/facility name: HI GRADE

Material Information

The concrete mix design number: SITI72A
The truck number from where the sample was collected: 180
The batch plant ticket number from where the sample was collected: 72437
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: DS 29 FIELD
Where the material sample would have been placed if not sampled: Unknown
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2015-12-07-1-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 12/21/2015
Verified Date: 12/21/2015
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.97 in
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 27.99 in^2
Compressive strength (to nearest 10 psi): 3570 psi
Maximum load on cylinder 1: 98730 lb
Maximum load on cylinder 2: 100960 lb
Compressive strength of cylinder 1: 3527.3 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 3607.0 psi
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 14 days
Age of specimen in hours: no data