Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215704 DEA: 020J9104 EFIS: 0219000174
QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS,MOD,SHA-89,139,299-VAR
Work Description: REPAIR UNSOUND CONCRETE, POLYESTER CONCRETE OVERLAYS, JOINT SEALS.
Location Description: LASSEN, MODOC, AND SHASTA COUNTIES AT VARIOUS LOCATIONS
Contractor Name: AMERICAN CIVIL CONSTRUCTORS WEST COAST LLC
Contractor Address: 2990 Bay Vista Court, Benicia, CA 95122
Resident Engineer: Tofael Anwar Structure Rep.: Unknown
DIME Sample ID: 2021-09-28-1
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 09/28/2021
Date that the sample was received by the laboratory/organization performing the testing: 09/28/2021
The quantity of what the sample constitutes: 36 Totes
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers and Polynt
DIME Test ID: 2021-09-28-1-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2021-09-28-1-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units
|
pounds/gallons
|
Liquid Density (pounds per gallon)
|
8.91
|
DIME Test ID: 2021-09-28-1-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
6
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.493 in
|
Sample 1 Ultimate strength
|
3086.3 psi
|
Sample 1 Thickness
|
0.254 in
|
Sample 1 Area
|
0.1252 in^2
|
Sample 1 Ultimate Strength Actual
|
386.4 lbs
|
Sample 1 percent elongation
|
56.4 %
|
Sample 1 Time
|
4 MM:SS
|
Sample 2 Width
|
0.492 in
|
Sample 2 Thickness
|
0.257 in
|
Sample 2 Area
|
0.1264 in^2
|
Sample 2 Ultimate strength
|
2706.5 psi
|
Sample 2 Ultimate Strength Actual
|
342.1 lbs
|
Sample 2 percent elongation
|
45.4 %
|
Sample 2 Time
|
3 MM:SS
|
Sample 3 Width
|
0.492 in
|
Sample 3 Thickness
|
0.249 in
|
Sample 3 Area
|
0.1225 in^2
|
Sample 3 Ultimate strength
|
3036.7 psi
|
Sample 3 Ultimate Strength Actual
|
372 lbs
|
Sample 3 percent elongation
|
54.4 %
|
Sample 3 Time
|
4 MM:SS
|
Sample 4 Width
|
0.491 in
|
Sample 4 Thickness
|
0.243 in
|
Sample 4 Area
|
0.1193 in^2
|
Sample 4 Ultimate strength
|
2989.1 psi
|
Sample 4 Ultimate Strength Actual
|
356.6 lbs
|
Sample 4 percent elongation
|
54.7 %
|
Sample 4 Time
|
4 MM:SS
|
Sample 5 Width
|
0.491 in
|
Sample 5 Thickness
|
0.234 in
|
Sample 5 Area
|
0.1149 in^2
|
Sample 5 Ultimate strength
|
2897.3 psi
|
Sample 5 Ultimate Strength Actual
|
332.9 lbs
|
Sample 5 percent elongation
|
52.9 %
|
Sample 5 Time
|
3 MM:SS
|
Sample 6 Width
|
0.492 in
|
Sample 6 Thickness
|
0.251 in
|
Sample 6 Area
|
0.1235 in^2
|
Sample 6 Ultimate strength
|
2658.3 psi
|
Sample 6 Ultimate Strength Actual
|
328.3 lbs
|
Sample 6 percent elongation
|
37.1 %
|
Sample 6 Time
|
2 MM:SS
|
Ultimate Strength Average
|
2896 psi
|
Percent Elongation Average
|
50 %
|
DIME Test ID: 2021-09-28-1-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination
|
46
|
DIME Test ID: 2021-09-28-1-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1
|
24hr
|
Maximum applied load (P) for Sample 1
|
1715.93 lb
|
Span length for Sample 1
|
9 in
|
Break location for Sample 1
|
PCC
|
Specimen defects/notes for Sample 1
|
no data
|
Surface type for Sample 1
|
SSD
|
Modulus of rupture (R) for Sample 1
|
857.965 psi
|
Curing history for Sample 2
|
24hr
|
Maximum applied load (P) for Sample 2
|
1663.73 lb
|
Span length for Sample 2
|
9 in
|
Break location for Sample 2
|
PCC
|
Specimen defects/notes for Sample 2
|
no data
|
Surface type for Sample 2
|
SSD
|
Modulus of rupture (R) for Sample 2
|
831.864 psi
|
Curing history for Sample 3
|
24hr
|
Maximum applied load (P) for Sample 3
|
1706.77 lb
|
Span length for Sample 3
|
9 in
|
Break location for Sample 3
|
PCC
|
Specimen defects/notes for Sample 3
|
no data
|
Surface type for Sample 3
|
SSD
|
Modulus of rupture (R) for Sample 3
|
853.383 psi
|
DIME Test ID: 2021-09-28-1-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid
|
153.9 mm
|
Room Temperature
|
75 f
|
Tare weight
|
0 grams
|
Initial weight
|
100 grams
|
Weight at 5 minutes
|
99.945 grams
|
Weight at 10 minutes
|
99.886 grams
|
Weight at 15 minutes
|
99.799 grams
|
Weight at 20 minutes
|
99.706 grams
|
Weight at 25 minutes
|
99.648 grams
|
Weight at 30 minutes
|
99.593 grams
|
Final weight
|
99.59 grams
|
Total weight loss
|
0.41 grams
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
Lid Factor
|
53.757 m^2
|
Volatile emission
|
22.04 grams/m^2
|