Print Report | Back to Test Summary

Testing Report for 2021-09-09-42-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 041J5694
EFIS: 0419000313
Project ID: 214601
QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-101-0.0/21.8
Work Description: Barrier modifications, overhead signs, freeway lighting and electronic toll system components
Location Description: SANTA CLARA AND SAN MATEO COUNTIES FROM 0.3 MILE NORTH OF SAN ANTONIO ROAD TO 0.3 MILE SOUTH OF GRAND AVENUE INTERCHANGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Douglas Inori
Structure Rep.: Tyler Pinell

Sample Information

DIME Sample ID: 2021-09-09-42
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - DME / District Lab
Sample Organization Contact: (510) 507-3456
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 9/9/2021
Date that the sample was received by the laboratory/organization performing the testing: 9/14/2021
The quantity of what the sample constitutes: 4 Bags
A brief description of the sample: 4 Bags of Aggregates
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hanson Sunol

Material Information

Source Identification (SMARA or name of Pit): 91-01-0011
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Hanson Sunol Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-09-09-42-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Date Tested: 9/23/2021
Verified Date: 10/14/2021
Submitted By Organization: CT D04 - DME / District Lab
Organization Address: 21339 Cabot Blvd,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 507-3456
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 97.4 %
Cumulative percent passing the 3/8 in. sieve: 86.3 %
Cumulative percent passing the #4 sieve: 32.5 %
Cumulative percent passing the #8 sieve: 17.4 %
Cumulative percent passing the #16 sieve: 12 %
Cumulative percent passing the #30 sieve: 8.8 %
Cumulative percent passing the #50 sieve: 6.5 %
Cumulative percent passing the #100 sieve: 4.3 %
Cumulative percent passing the #200 sieve: 3.1 %