Print Report | Back to Test Summary

Testing Report for 2021-10-04-2-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080C2514
EFIS: 0816000076
Project ID: 212112
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Matt Antonelli
Structure Rep.: Faisal Zahlout

Sample Information

DIME Sample ID: 2021-10-04-2
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/4/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/8/2021
The quantity of what the sample constitutes: 3 Samples out of 40 pcs.
A brief description of the sample: F1554 Grade 55 HDG Anchor Bolts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Circle Corp

Material Information

Rocap Number(s):
Heat Number(s): Nucor 1201034504
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: ASTM F1554
Bolt Length(s): 20"
Nut Specification: N/A
Washer Specification: N/A
Finish: ASTM F1554
Diameter/Size: 1-1/2"
Bolt Mfg. Lot Number: 120103450420
Rocap Test Requirement(s): Unknown
Lubricant Requirements(s): Unknown

Test Information

DIME Test ID: 2021-10-04-2-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Date Tested: 10/14/2021
Verified Date: 10/14/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Heat Number Diameter (in) Area (sqin) Stress at Offset (psi) Tensile Strength (psi) Elongation in 4 x d (%) Tested By
1 1201034504 0.505 0.2 60208 82698 27.4 bewing
UTM: 67kip
Temperature: 72 f