Print Report | Back to Test Summary

Testing Report for 2021-09-27-38-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 010C5704
EFIS: 0113000009
Project ID: 215161
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-69.8/75.2
Work Description: PLACE RHMA-G, HMA AND CONCRETE BARRIER.
Location Description: HUMBOLDT COUNTY IN AND NEAR EUREKA FROM 0.8 MILE SOUTH OF TOMPKINS HILL ROAD OVERHEAD TO 0.4 MILE NORTH OF HERRICK AVENUE OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Joaquin Rodriguez
Structure Rep.: Jarred Burrows

Sample Information

DIME Sample ID: 2021-09-27-38
TL Number from the TL Form: c581668
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 9/27/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/1/2021
The quantity of what the sample constitutes: 1 quart can
A brief description of the sample: PG64-16 Rubber Blend
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser Plant B

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-09-27-38-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Date Tested: 10/6/2021
Verified Date: 10/6/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Determination: Unworked Penetration
Unworked Penetration: 42 0.1 mm