Print Report | Back to Test Summary

Testing Report for 2015-11-12-6-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07288604
EFIS: 0700021080
Project ID: 208945
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer:
Structure Rep.:

Sample Information

DIME Sample ID: 2015-11-12-6
TL Number from the TL Form: C927131
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 11/12/2015
Date that the sample was received by the laboratory/organization performing the testing: 11/17/2015
The quantity of what the sample constitutes: 1
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden

Material Information

Comments: Unknown
Reel/Coil/Pack Number(s): S333550 1
Number of Coils: 1
Group Number: Unknown
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0587515
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden

Test Information

DIME Test ID: 2015-11-12-6-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Date Tested: 11/17/2015
Verified Date: 11/18/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Dia of the Center Wire (in) Dia of the Outer Wire 1 (in) Dia of the Outer Wire 2 (in) Dia of the Outer Wire 3 (in) Dia of the Outer Wire 4 (in) Dia of the Outer Wire 5 (in) Dia of the Outer Wire 6 (in) Area (sqin)
.208 .197 .197 .197 .197 .197 .197 0.217