Sample Record for 2021-10-05-12
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993111 DEA: 010L2304 EFIS: 0121000086
QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-15.1/15.5
Work Description: Last Chance Grade Landslide Repair
Location Description: Last Chance Grade at Hwy 101 PM 15.1 to 15.5
Contractor Name: Stewart Engineering
Contractor Address: P.O. Box 990010, Redding, CA 96099
Resident Engineer: Aaron Valley Structure Rep.: Joshua Lee
Sample Information
DIME Sample ID: 2021-10-05-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 10/05/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/05/2021
The quantity of what the sample constitutes: 49
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Material Information
Comments:
Reel/Coil/Pack Number(s):
Number of Coils:
Group Number: 10983
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0224548, S0225051, S0225050, S0225044, S0225046
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire
Test Results
Test 1 of 13
DIME Test ID: 2021-10-05-12-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
This test has been superseded on 11/01/2021. The corrected test ID is: 2021-10-05-12-12
Reason: retested
Test 2 of 13
DIME Test ID: 2021-10-05-12-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
This test has been superseded on 11/01/2021. The corrected test ID is: 2021-10-05-12-13
Reason: retested
Test 3 of 13
DIME Test ID: 2021-10-05-12-3
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/07/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0225051 | S335922-1 | 0.215 | 60460 | 57957.7 | 0 | 2.01 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
Test 4 of 13
DIME Test ID: 2021-10-05-12-4
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/07/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0225051 | S335922-4 | 0.215 | 60578 | 57031.9 | 28.7 | 1.7 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
Test 5 of 13
DIME Test ID: 2021-10-05-12-5
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/07/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0225050 | S335924-4 | 0.215 | 60594 | 58220.7 | 0 | 1.59 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
Test 6 of 13
DIME Test ID: 2021-10-05-12-6
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/07/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0225050 | S335924-5 | 0.215 | 60676 | 57004.6 | 28.8 | 1.7 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
Test 7 of 13
DIME Test ID: 2021-10-05-12-7
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/07/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0225044 | S335925-2 | 0.215 | 61009 | 58007.6 | 0 | 1.72 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
Test 8 of 13
DIME Test ID: 2021-10-05-12-8
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/07/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0225044 | S335925-4 | 0.215 | 61753 | 59476.1 | 0 | 1.62 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
Test 9 of 13
DIME Test ID: 2021-10-05-12-9
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/07/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0225046 | S335927-4 | 0.215 | 60974 | 58348.3 | 28.8 | 1.78 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
Test 10 of 13
DIME Test ID: 2021-10-05-12-10
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/07/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0225046 | S335928-3 | 0.215 | 60162 | 56189.9 | 28.7 | 1.75 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
Test 11 of 13
DIME Test ID: 2021-10-05-12-11
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/07/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0225051 | S335922-5 | 0.215 | 60304 | 56776.7 | 28.6 | 1.65 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
Test 12 of 13
DIME Test ID: 2021-10-05-12-12
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 11/01/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
The test was superseded from test ID: 2021-10-05-12-1
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0224548 | S335920-1 | 0.217 | 61332 | 58657.4 | 0 | 1.84 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
Test 13 of 13
DIME Test ID: 2021-10-05-12-13
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 11/01/2021
Date Tested: 10/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
The test was superseded from test ID: 2021-10-05-12-2
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0224548 | S335920-3 | 0.217 | 61075 | 57485.4 | 28.2 | 1.6 | bewing |
| |
UTM
|
120KIP
|
Temperature
|
72 f
|
Extensometers
|
E88768
|