Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2015-11-10-4
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 11/10/2015
Date that the sample was received by the laboratory/organization performing the testing: 11/30/2015
The quantity of what the sample constitutes: 26
A brief description of the sample: .52in Prestressing Strand
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden
DIME Test ID: 2015-11-10-4-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 02/24/2016
Date Tested: 11/13/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
2
|
Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) | .182 | .174 | .174 | .174 | .174 | .174 | .174 | 0.169 | .182 | .174 | .174 | .174 | .174 | .174 | .174 | 0.169 |
| |
DIME Test ID: 2015-11-10-4-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 02/24/2016
Date Tested: 11/13/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
2
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0281162 | S950140-1 | 0.169 | 46934 | 43571 | 28 | 1.65 | Brian | S0281162 | S950143-5 | 0.169 | 47453 | | 28.4 | 1.81 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
72 F
|
Extensometers
|
E88768
|