REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Scott Hislop |
Date Reported: |
11/04/2015 |
|
Address: |
TL Number: |
052737 |
||
City: |
||||
Project Name: REPLACE CULVERT WITH RAMMING 108" STEEL CASING. |
||||
Prime Contractor: DRILL TECH DRILLING & SHORING INC |
||||
Sample Taken Date: |
10/07/2015 |
Mix Design: |
unknown |
|
Contractor: Unknown |
Location: SONOMA COUNTY NEAR TIMBER COVE AT 2.0 MILES SOUTH OF FORT ROSS HISTORIC PARK |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: wing walls |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 117220 | 4131.8 | 1 |
2 | 6.00 | 28.27 | 120646 | 4267.6 | 1 |
DIME Test ID: 2015-10-07-4-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4200
Age of specimen: 28 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |