Print Report | Back to Test Summary

Testing Report for 2015-10-05-2-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07121844
EFIS: 0700000117
Project ID: 3807
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-42.8/47.3
Work Description: CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: James Shih
Structure Rep.: Matthew Remo

Sample Information

DIME Sample ID: 2015-10-05-2
TL Number from the TL Form: 1051
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/5/2015
Date that the sample was received by the laboratory/organization performing the testing: 10/8/2015
The quantity of what the sample constitutes: 4
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 819-51
Structure unique identifier: APPROACH SLAB AT ALAMEDA AVE UC LEFT BR
Structure name: ABUTMENT 1
The fabricator/manufacturer/facility name: NATIONAL

Material Information

The concrete mix design number: SM 40325
The truck number from where the sample was collected: 393
The batch plant ticket number from where the sample was collected: 186440
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: CGUTE
Where the material sample would have been placed if not sampled: Unknown
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2015-10-05-2-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 11/2/2015
Verified Date: 11/2/2015
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength (to nearest 10 psi): 4330 psi
Maximum load on cylinder 1: 121630 lb
Maximum load on cylinder 2: 123920 lb
Compressive strength of cylinder 1: 4287.3 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 4368.0 psi
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data