Testing Report for 2015-10-02-3-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080F5404
EFIS: 0800000136
Project ID: 209217
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-91,15-0.0/13.04, 35.64/45.14
Work Description: SR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description: 08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Salim Khalil
Structure Rep.: Alex Angha

Sample Information

DIME Sample ID: 2015-10-02-3
TL Number from the TL Form: SRL 96
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/2/2015
Date that the sample was received by the laboratory/organization performing the testing: 10/5/2015
The quantity of what the sample constitutes: 6
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 888 SRL-96
Structure unique identifier: 91 CIP
Structure name: RW 214B FTG
The fabricator/manufacturer/facility name: NP

Material Information

The concrete mix design number: 5645
The truck number from where the sample was collected: 189
The batch plant ticket number from where the sample was collected: 104009297
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: LOAD 7
Where the material sample would have been placed if not sampled: Unknown
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2015-10-02-3-3
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 10/30/2015
Verified Date: 10/30/2015
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4580 psi
Maximum load on cylinder 1: 128880 lb
Maximum load on cylinder 2: 130320 lb
Compressive strength of cylinder 1: 4558.9 psi
Type of fracture pattern of cylinder 1: 3
Compressive strength of cylinder 2: 4609.8 psi
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data