Print Report | Back to Sample Detail

Sample Record for 2021-09-13-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215109 DEA: 081C8504 EFIS: 0813000047 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-0.0/5.8
Work Description: ROADWAY EXCAVATION, HOT MIX ASPHALT, AND STRUCTURAL SHOTCRETE WALLS.
Location Description: RIVERSIDE COUNTY NEAR LAKE ELSINORE FROM ORANGE COUNTY LINE TO MONTE VISTA STREET
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 38000 MONROE STREET, INDIO, CA 92203
Resident Engineer: Osama Abdalla Structure Rep.: Ryan Kash (Reports)

Sample Information

DIME Sample ID: 2021-09-13-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Verification
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 09/13/2021
Date that the sample was received by the laboratory/organization performing the testing: 09/20/2021
The quantity of what the sample constitutes: 2
A brief description of the sample: #8 Grade 75 All Thread Bar
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Engineering San Diego

Material Information

Production or Authorization Testing: Authorization Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Plain
Rebar Size: #8
Nut Specification for Threaded Bar: ASTM A108
System Manufacturer: Williams Form Engineering San Diego
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: ASTM A123 galvanized
Bar Heat Number(s): 100108552
Nut Heat Number(s): 8391581
Bar Lot Number: 10010855221
Nut Lot Number: 8U3D
Coupler Heat Number(s): A186720
Coupler Grade: 1215

Test Results

Test 1 of 3

DIME Test ID: 2021-09-13-1-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 09/27/2021
Date Tested: 09/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Stripped Coupler #8U3D
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
No.8/25mm0.7910751594434-100Nut Stripped Coupler #8U3Dfsaylor
Temperature 72 f
UTM 400kip

Test 2 of 3

DIME Test ID: 2021-09-13-1-2
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 09/27/2021
Date Tested: 09/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Grip pull Coupler Broke in Half
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
No.8/25mm0.79123145110849-100Grip pull Coupler Broke in Halffsaylor
Temperature 72 f
UTM 400kip

Test 3 of 3

DIME Test ID: 2021-09-13-1-3
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 09/27/2021
Date Tested: 09/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Girp Pull
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
No.8/25mm0.791266611245978.57Girp Pullfsaylor
Temperature 72 f
UTM 400kip