Print Report | Back to Test Summary

Testing Report for 2021-08-28-3-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 032G1104
EFIS: 0320000230
Project ID: 215572
QA Service Level: 1
DIST-CO-RTE-PM: 03-GLE-162-66.6/76.3
Work Description: PLACE RHMA AND COLD IN-PLACE RECYCLE.
Location Description: GLENN COUNTY IN AND NEAR WILLOWS FROM 0.2 MILE EAST OF N SHASTA STREET TO 1.0 MILE EAST OF ROAD X
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Dan Reechs
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-08-28-3
TL Number from the TL Form: c694337
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 8/28/2021
Date that the sample was received by the laboratory/organization performing the testing: 9/17/2021
The quantity of what the sample constitutes: 1 gallon can
A brief description of the sample: Asphalt rubber binder
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pavement Coatings

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-08-28-3-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Date Tested: 9/23/2021
Verified Date: 9/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: does not comply
Additional Comments When Verified : Failed D5329

Submitted Test Results

Temperature: 25 C
Final Dial reading (F1): 94 mm
Ball Penetration (P1): 6 mm
Final Dial reading (F2): 95 mm
Ball Penetration (P2): 6 mm
Final Dial reading (F3): 94 mm
Ball Penetration (P3): 5 mm
Resilience 1: 12 %
Resilience 2: 11 %
Resilience 3: 11 %
Average Resilience: 11 %