Print Report | Back to Sample Detail

Sample Record for 2021-07-21-59

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214466 DEA: 081F1414 EFIS: 0815000231 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-15-54.2/54.3
Work Description: Slab & lane replacement with JPCP & precast conc pavement, place HMA.
Location Description: Riverside and San Diego County
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Road, Suite 200, Westlake Village, CA 91361
Resident Engineer: Mike Bergevin Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-07-21-59
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Sample Organization Contact: (760) 252-9216
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/21/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/22/2021
The quantity of what the sample constitutes: 1Bag
A brief description of the sample: 3/4 RHMA-G 1/2"
From where was the sample collected: Distributor
Laboratory sample identification: test 1 214 tons out
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCA-Lake Elsinore

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2021-07-21-59-1
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 09/22/2021
Date Tested: 07/22/2021
Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: kaushalkumar.talati@dot.ca.gov
Organization Phone: (951) 840-8328
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 0 %
Cumulative percent passing the 1 1/2 in. sieve 0 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 93 %
Cumulative percent passing the 3/8 in. sieve 80 %
Cumulative percent passing the #4 sieve 38 %
Cumulative percent passing the #8 sieve 28 %
Cumulative percent passing the #16 sieve 18 %
Cumulative percent passing the #30 sieve 12 %
Cumulative percent passing the #50 sieve 8 %
Cumulative percent passing the #100 sieve 8 %
Cumulative percent passing the #200 sieve 4.0 %