Sample Record for 2015-10-14-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 209217 DEA: 080F5404 EFIS: 0800000136 COOP: 081468
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-91,15-0.0/13.04, 35.64/45.14
Work Description: SR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description: 08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
Contractor Name: Atkinson Walsh, Joint Venture
Contractor Address: 1785 Sampson Ave, Corona, CA 92879
Resident Engineer: Richard Hebert Structure Rep.: Cyrus Shahinpar
Sample Information
DIME Sample ID: 2015-10-14-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 10/14/2015
Date that the sample was received by the laboratory/organization performing the testing: 10/16/2015
The quantity of what the sample constitutes: 5
A brief description of the sample: Bearing Pad
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal
Material Information
Mfg. Lot Number(s): 140971
Material/Compound/Elastomer ID: 140971
Samples Representing: 5
Description (size): 6in x 20in x 20in
Comments: Unknown
Description (Number of Shims): 12
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal
Batch Number: NA
Test Results
Test 1 of 4
DIME Test ID: 2015-10-14-1-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 10/20/2015
Date Tested: 10/16/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
56
|
Reading #2
|
55
|
Reading #3
|
56
|
Reading #4
|
55
|
Reading #5
|
55
|
Mean
|
55.4
|
Test 2 of 4
DIME Test ID: 2015-10-14-1-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 10/20/2015
Date Tested: 10/16/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
no data
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.071 in
|
Sample 1 Thickness all Within 0.003 inch?
|
yes
|
Sample 1 Ultimate Tensile
|
2359.6 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.072 in
|
Sample 2 Thickness all Within 0.003 inch?
|
yes
|
Sample 2 Ultimate Tensile
|
2444.4 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.075 in
|
Sample 3 Thickness all Within 0.003 inch?
|
yes
|
Sample 3 Ultimate Tensile
|
2872.3 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2444.4 lbf/in^2
|
Test 3 of 4
DIME Test ID: 2015-10-14-1-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 10/20/2015
Date Tested: 10/16/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
no data
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.072 in
|
Sample 1 Tear Strength
|
208.3 lbf / in
|
Sample 2 Median Thickness
|
0.071 in
|
Sample 2 Tear Strength
|
239.4 lbf / in
|
Sample 3 Median Thickness
|
0.076 in
|
Sample 3 Tear Strength
|
236.8 lbf / in
|
Median of the Tear Strength Values
|
236.8 lb/in
|
Test 4 of 4
DIME Test ID: 2015-10-14-1-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 10/20/2015
Date Tested: 10/19/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified: