Print Report | Back to Test Summary

Testing Report for 2021-09-08-7-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 010C5704
EFIS: 0113000009
Project ID: 215161
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-69.8/75.2
Work Description: PLACE RHMA-G, HMA AND CONCRETE BARRIER.
Location Description: HUMBOLDT COUNTY IN AND NEAR EUREKA FROM 0.8 MILE SOUTH OF TOMPKINS HILL ROAD OVERHEAD TO 0.4 MILE NORTH OF HERRICK AVENUE OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Joaquin Rodriguez
Structure Rep.: Jarred Burrows

Sample Information

DIME Sample ID: 2021-09-08-7
TL Number from the TL Form: c972624
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 9/8/2021
Date that the sample was received by the laboratory/organization performing the testing: 9/13/2021
The quantity of what the sample constitutes: 1 can
A brief description of the sample: PG64-16
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser Plant B

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number: 1
Sublot number: 1
Tank number:
Time of sample:
HMA Supplier:
Asphalt Binder Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-09-08-7-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Date Tested: 9/14/2021
Verified Date: 9/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications ORG
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Phase: Original binder
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.204 kPa
Phase Angle (δ) (for the 10 cycles): 84.7 degree
Complex Modulus (G*) (for the 10 measurements): 1.697 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.70 kPa