Print Report | Back to Sample Detail

Sample Record for 2021-09-09-19

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215687 DEA: 074W6104 EFIS: 0719000104 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-18-0.0/4.5
Work Description: PLACE RUBBERIZED HMA (GAP GRADED).
Location Description: LOS ANGELES COUNTY NEAR LLANO FROM SAN BERNARDINO COUNTY LINE TO JUNCTION ROUTE 138
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 4820 Mcgrathst. STE 101, Ventura CA. 93003
Resident Engineer: Fred Tieu Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-09-09-19
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Per Request
Type of Material: Asphalt Binder
Sample Taken Date: 09/09/2021
Date that the sample was received by the laboratory/organization performing the testing: 09/10/2021
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: PG Asphalt Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0524-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite-Llano

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 8

DIME Test ID: 2021-09-09-19-1
Test Method: AASHTO T228-09r13: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Verified Date: 09/15/2021
Date Tested: 09/15/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Specific Gravity 1.015

Test 2 of 8

DIME Test ID: 2021-09-09-19-2
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 09/15/2021
Date Tested: 09/15/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Any material loss from containers during heating process/testing? No
Mass of empty container #1 167.303 grams
Mass of empty container #2 169.565 grams
Mass of container #1 before test (m1i) 201.963 grams
Mass of container #2 before test (m2i) 204.563 grams
Mass of container #1 after test (m1f) 201.968 grams
Mass of container #2 after test (m2f) 204.569 grams
Average mass change 0.016 percent

Test 3 of 8

DIME Test ID: 2021-09-09-19-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/15/2021
Date Tested: 09/15/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Plate Diameter 25 mm
Phase Angle (δ) (for the 10 cycles) 89.2 degree
Dynamic Shear, G*/sin(δ) 1.35 kPa

Test 4 of 8

DIME Test ID: 2021-09-09-19-4
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/15/2021
Date Tested: 09/15/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Phase Angle (δ) (for the 10 cycles) 88.4 degree
Dynamic Shear, G*/sin(δ) 2.31 kPa
(G*) x sin(δ)= no data

Test 5 of 8

DIME Test ID: 2021-09-09-19-5
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 09/21/2021
Date Tested: 09/15/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s? Pa-s
Time of test 07:20 HH:MM
Test Temperature 135 C
Speed 50 rpm
Spindle size 21 in
Torque 29 %
Viscosity reading #1 (A) 0.291 Pa-s
Viscosity reading #2 (B) 0.294 Pa-s
Viscosity reading #3 (C) 0.296 Pa-s
Average viscosity 0.294 Pa-s

Test 6 of 8

DIME Test ID: 2021-09-09-19-6
Test Method: AASHTO T44-18: Standard Method of Test for Solubility of Bituminous Materials
Verified Date: 09/21/2021
Date Tested: 09/15/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Was test performed on residue from distillation or evaporation? Evaporation
Soluble, percent 99.9 %
Insoluble, percent 0.1 %

Test 7 of 8

DIME Test ID: 2021-09-09-19-7
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 09/21/2021
Date Tested: 09/16/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is a normal test obtainable? Yes
Number of replicates tested One
Ductility of test #1 (D1) 75 cm
Ductility of sample 75 cm

Test 8 of 8

DIME Test ID: 2021-09-09-19-8
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 10/03/2021
Date Tested: 09/29/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Phase Angle (δ) (for the 10 cycles) 60.9 degree
Dynamic Shear, G*/sin(δ) 3420.00 kPa
(G*) x sin(δ)= no data