Print Report | Back to Test Summary

Testing Report for 2021-08-16-14-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 040A0204
EFIS: 0400000129
Project ID: 215486
QA Service Level: 1
DIST-CO-RTE-PM: 04-SON-1-15-15.7
Work Description: CONSTRUCTION ON STATE HIGHWAY IN SONOMA COUNTY NEAR BODEGA BAY FROM 0.2 MILE SOUTH TO 0.4 MILE NORTH OF SCOTTY CREEK CULVERT.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Syd Valeh
Structure Rep.: Bunma Nou

Sample Information

DIME Sample ID: 2021-08-16-14
TL Number from the TL Form: 120796
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 227-7283
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 8/16/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/20/2021
The quantity of what the sample constitutes: 9 cylinders
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: RR Canyon Rock, Forestville
The fabricator/manufacturer/facility name: Cemex Victorville

Material Information

The concrete mix design number: 72105003R
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2021-08-16-14-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 9/13/2021
Verified Date: 9/13/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.02 in
Average diameter of cylinder 3: 4.02 in
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength (to nearest 10 psi): 6670 psi
Maximum load on cylinder 1: 85480 lbf
Maximum load on cylinder 2: 81684 lbf
Maximum load on cylinder 3: 86794 lbf
Compressive strength of cylinder 1: 6735.0 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 6436.0 psi
Compressive strength of cylinder 3: 6838 psi
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: no data