Print Report | Back to Test Summary

Testing Report for 2021-08-27-27-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 010L2304
EFIS: 0121000086
Project ID: 993111
QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-15.1/15.5
Work Description: Last Chance Grade Landslide Repair
Location Description: Last Chance Grade at Hwy 101 PM 15.1 to 15.5
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Aaron Valley
Structure Rep.: Thomas Norris

Sample Information

DIME Sample ID: 2021-08-27-27
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 8/27/2021
Date that the sample was received by the laboratory/organization performing the testing: 9/8/2021
The quantity of what the sample constitutes: 52
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments:
Reel/Coil/Pack Number(s):
Number of Coils:
Group Number: 10978
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0549921, S0559521, S0549721, S0550021, S0549821
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire

Test Information

DIME Test ID: 2021-08-27-27-4
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Date Tested: 9/10/2021
Verified Date: 9/14/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Heat Number Coil Area (sqin) Peak Load (lbf) Load at EUL (lbf) Chord Modulus (Msi) Elongation (in) Tested By
S0559521 S335875-1 0.218 61049 56177.8 28.8 1.99 bewing
UTM: 120kip
Temperature: 72 f
Extensometers: no data