Print Report | Back to Test Summary

Testing Report for 2021-08-13-35-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 040W3904
EFIS: 0420000212
Project ID: 215605
QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-160-L1.1/0.6
Work Description: COLD PLANE AC PAVEMENT AND PLACE HMA (A).
Location Description: CONTRA COSTA COUNTY IN ANTIOCH FROM 0.2 MILE SOUTH OF MAIN STREET TO 0.1 MILE NORTH OF WILBUR AVENUE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-08-13-35
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - DME / District Lab
Sample Organization Contact: (510) 507-3456
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 8/13/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/13/2021
The quantity of what the sample constitutes: 25 Boxes-Hot Mix Asphalt
A brief description of the sample: 25 Boxes-Hot Mix Asphalt
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: ABM ANTIOCH

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-08-13-35-2
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Date Tested: 8/24/2021
Verified Date: 9/9/2021
Submitted By Organization: CT D04 - DME / District Lab
Organization Address: 21339 Cabot Blvd,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 507-3456
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Average Dry Tensile Strength: 197 psi
Average Wet Tensile Strength: 159 psi
Tensile Strength Ratio: 0.81