Print Report | Back to Sample Detail

Sample Record for 2021-09-01-22

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215530 DEA: 051N1704 EFIS: 0520000136 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-135-1.0/R7.2
Work Description: Construct pavement using partial depth recycling and pave with RHMA
Location Description: CONSTRUCTION ON STATE HIGHWAY IN SANTA BARBARA COUNTY NEAR LOS ALAMOS FROM 0.3 MILE NORTH OF DEN STREET TO SAN ANTONIO CREEK BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 2023 Preisker Lane, Suite B, Santa Maria, CA 93454
Resident Engineer: Lilian Bennetzen Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-09-01-22
TL Number from the TL Form: 210901B
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 09/01/2021
Date that the sample was received by the laboratory/organization performing the testing: 09/07/2021
The quantity of what the sample constitutes: 2 cans - load 12
A brief description of the sample: Asphalt Binder PG 64-10
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction

Material Information

Performance Grade: PG 64-10
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier: Granite
Certified Asphalt Supplier: Valero Marketing & Supply - Wilmington CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2021-09-01-22-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 09/15/2021
Date Tested: 09/09/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: as per 2018 standard specs
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Any material loss from containers during heating process/testing? No
Mass of empty container #1 175.657 grams
Mass of empty container #2 174.577 grams
Mass of container #1 before test (m1i) 211.194 grams
Mass of container #2 before test (m2i) 209.822 grams
Mass of container #1 after test (m1f) 211.051 grams
Mass of container #2 after test (m2f) 209.680 grams
Average mass change -0.403 percent

Test 2 of 5

DIME Test ID: 2021-09-01-22-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/15/2021
Date Tested: 09/08/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications Original
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.00 %
Stress Amplitude 0.163 kPa
Phase Angle (δ) (for the 10 cycles) 86.4 degree
Complex Modulus (G*) (for the 10 measurements) 1.362 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 1.36 kPa

Test 3 of 5

DIME Test ID: 2021-09-01-22-3
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/15/2021
Date Tested: 09/08/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.00 %
Stress Amplitude 0.341 kPa
Phase Angle (δ) (for the 10 cycles) 82.5 degree
Complex Modulus (G*) (for the 10 measurements) 3.412 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 3.44 kPa

Test 4 of 5

DIME Test ID: 2021-09-01-22-4
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/15/2021
Date Tested: 09/13/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter 8 mm
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.00 %
Stress Amplitude 25.370 kPa
Phase Angle (δ) (for the 10 cycles) 51.3 degree
Complex Modulus (G*) (for the 10 measurements) 2536.589 kPa
Test Temperature (Specimen 1) 31.0 C
(G*) x sin(δ)= 1980 kPa

Test 5 of 5

DIME Test ID: 2021-09-01-22-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 09/15/2021
Date Tested: 09/14/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 standard specification
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s 0.0 C
Maximum test bath temperature at 240 s 0.0 C
Time of test load application no data HH:MM:SS
File name of test data no data
Time beam in bath no data
Time test started no data HH:MM:SS
Flags issued by software during test no data
Correlation coefficient (R²) 0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 0.0 mN
Deflection at time 0.0 s 0.000 µm
Load at time 0.5 s 0.0 mN
Deflection at time 0.5 s 0.000 µm
Load at 60.0 s 987.0 mN
Beam deflection 60.0 s 2.285 µm
Measured Stiffness Modulus 60.0 s 34.800 mPa
Estimated Stiffness Modulus 60.0 s 34.800 mPa
Difference between stiffness moduli 60.0 s no data
Estimated m-value 60.0 s 0.463