Print Report | Back to Test Summary

Testing Report for 2021-09-07-12-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: ASCP
EFIS: ASCP
Project ID: 44444
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-09-07-12
TL Number from the TL Form:
Sample Submitted By Organization: HollyFrontier Asphalt Company LLC
Sample Organization Contact: (623) 939-3311
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 9/7/2021
Date that the sample was received by the laboratory/organization performing the testing: 9/7/2021
The quantity of what the sample constitutes: 2 quart cans, split sample
A brief description of the sample: Asphalt Binder
From where was the sample collected: Supplier
Laboratory sample identification: 21-200
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: HollyFrontier-Glendale,AZ

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number: 501
Time of sample: 9/7/2021 8:30
HMA Supplier:
Asphalt Binder Supplier: Holly Frontier Asphalt Company - Glendale AZ
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-09-07-12-4
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Date Tested: 9/7/2021
Verified Date: 9/9/2021
Submitted By Organization: HollyFrontier Asphalt Company LLC
Organization Address: 7110 W Northern Avenue,
Organization City: Glendale
Organization State: AZ
Organization Zipcode: 85303
Organization Email: thomas.ludlum@hollyfrontier.com
Organization Phone: (623) 939-3311
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Phase: Original binder
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 0.0 degree
Dynamic Shear, G*/sin(δ): 1.21 kPa