Print Report | Back to Test Summary

Testing Report for 2021-08-26-13-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 031G7404
EFIS: 0319000238
Project ID: 215448
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-50-Var
Work Description: REMOVE BOLTS AND ADD PAINTED STRUCTURAL STEEL PLATES.
Location Description: SACRAMENTO COUNTY IN SACRAMENTO AT SACRAMENTO RIVER VIADUCT AND RAMP A4
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Deya Dean Elghassein
Structure Rep.: Eric Paul Duray

Sample Information

DIME Sample ID: 2021-08-26-13
TL Number from the TL Form: c658227
Sample Submitted By Organization: CT QASI - Bay Area Field Laboratory
Sample Organization Contact: (707) 649-5453
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 8/26/2021
Date that the sample was received by the laboratory/organization performing the testing: 9/2/2021
The quantity of what the sample constitutes: 33 each
A brief description of the sample: 7/8" A325 fastener assemblies
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CK Johnson Industries

Material Information

Rocap Number(s): 435991A
Heat Number(s): bolt-100202821 washer- 209071 nut- 453592B
Nut Mfg. Lot Number(s): Nucor- 453592B
Washer Mfg. Lot Number(s): Wrought- 10444 9874
Bolt Specification: A325
Bolt Length(s): 5.5"
Nut Specification: A563DH
Washer Specification: F436
Finish: HDG
Diameter/Size: 7/8"
Bolt Mfg. Lot Number: Nucor- 435991A
Rocap Test Requirement(s): yes
Lubricant Requirements(s): yes

Test Information

DIME Test ID: 2021-08-26-13-3
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Date Tested: 9/8/2021
Verified Date: 9/9/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Sample No.: 7A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 435991A
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 USA N
Size: .875 in
Bolt Length: 5.5 in
Pitch Diameter: 0.809 in
Pitch Diameter 2nd: no data