Print Report | Back to Test Summary

Testing Report for 2021-09-03-1-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 112N0084
EFIS: 1117000153
Project ID: 215589
QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-7,8,78,86,98,111-Var
Work Description: METHACRYLATE BRIDGE DECKS, REPAIR SPALLS AND REPLACE JOINT SEALS.
Location Description: IMPERIAL COUNTY AT VARIOUS LOCATIONS.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: David Toci
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-09-03-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 227-7283
Type of Sample: Authorization
Type of Material: Methacrylate
Sample Taken Date: 9/3/2021
Date that the sample was received by the laboratory/organization performing the testing: 9/3/2021
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: HMWM
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Transpo Industries Inc

Material Information

Mfg. Lot Number(s): B0615217010
Batch number: B0615217010
Mix number: 3540

Test Information

DIME Test ID: 2021-09-03-1-1
Test Method: CONCLP 4-16: HMWM
Date Tested: 9/3/2021
Verified Date: 9/3/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test: Bond Strength was not performed due to material failing other tests. Tack Free time went past maximum time of 400 minutes and test was ended at 400 minutes.
Test Result Compliance: does not comply
Additional Comments When Verified :

Submitted Test Results

Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 28.5
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 0.99
Volatile content (ASTM D 2369) 30% max: 40.4
Flash point (ASTM D 3828) more than 180 deg F: 200
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: no data
Tack free time, 400 minutes max: 499