Print Report | Back to Test Summary

Testing Report for 2021-08-26-3-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 112T2174
EFIS: 1116000131
Project ID: 211848
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-R37.4 - R46.5
Work Description: (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location Description: IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Steve McMillan
Structure Rep.: Phong Le

Sample Information

DIME Sample ID: 2021-08-26-3
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Bay Area Field Laboratory
Sample Organization Contact: (707) 649-5453
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 8/26/2021
Date that the sample was received by the laboratory/organization performing the testing: 9/1/2021
The quantity of what the sample constitutes: 1 lot of 450
A brief description of the sample: U-bolt with HHN and Acorn Nuts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Portland Bolt - Oregon

Material Information

Rocap Number(s): Not applicable
Heat Number(s): 10712390 Bolt, 6215287403 HHN, 194689 Acorn Nut
Nut Mfg. Lot Number(s): 33753
Washer Mfg. Lot Number(s): not applicable
Bolt Specification: ASTM A193B7
Bolt Length(s): 9-1/2"
Nut Specification: ASTM A194 Grade 2H
Washer Specification: ASTM A29
Finish: HDG
Diameter/Size: 5/8" x 9-1/2" x 3-3/8" x 4"
Bolt Mfg. Lot Number: not applicable
Rocap Test Requirement(s): Not applicable
Lubricant Requirements(s): Yes

Test Information

DIME Test ID: 2021-08-26-3-4
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 9/2/2021
Verified Date: 9/2/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A194
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
1A 33753-6215287403 39618 A194
UTM: 400kip
Temperature: 72 f